Features and Advantages

Headway HUBT-20P is our major achievement after many years of system improvement. H. Pylori infection can be accurately
detected using this 14C-UBT system which tracks the 14C-labeled isotope in the breath exhaled by the patients,

thus providing excellent medical support for patients and doctors.

Mature circuit design, stable and reliable components, and highly modularized design have greatly improved after-sales service experience. The detector has stood the test of the market and proven its enduring vitality because of its unparalleled performance stability.

The tolerance of relative variation of 14C detection efficiency is ≤30% after operating for successive 48 hours

The efficiency of detection on 14C unquenched standard source is ≥15%

The background count of 14C is ≤50CPM

A fully-automated design enables easy, automatic measurement without pushing any buttons.

The detector allows automatic fault diagnosis and correction.

The detector can be either operated alone or connected to a PC. It has a built-in printer for automatic printing.

The detector is connected to the local area network of the hospital and can achieve interconnection.

The innovative design of a cartridge and a disposable mouthpiece makes UBT more convenient. Just one breath is needed to detect H. Pylori infection.

  • The patient takes a 14C-urea capsule

  • Wait for 15 min

  • The patient exhales on to the card without inhaling, until the card's color changes from orange to yellow

  • Use the HUBT-20P test collection card for the diagnosis (positive/negative)

  • Product Highlight:

    High accuracy with CPM result

    Lightweight and compact for easy portability and handling

    User-friendly design

    Analysis available on site within 4′10″

    Automatic measurement and patient data storage

    PC connection, professional software

  • Physical Specifications

    Dimensions:

    ·Length: 320 mm

    ·Width: 300 mm

    ·Height: 280 mm

    Weight: 9 Kg

  • Operating Condition

    Ambient Temperature: 5℃ - 40℃

    Relative Humidity: ≤ 75%

    Preheating time: ≥ 30 min

    Atmospheric pressure: 75 Kpa - 106 Kpa

  • Performance

    The efficiency of detection on 14C unquenched standard source is ≥15%

    The background count of 14C is ≤ 50 CPM

    The tolerance of relative variation of 14C detection efficiency is ≤ 30% after operating for successive 48 hours

  • Storage and transportation

    Ambient temperature: -10℃ - +55℃

    Relative humidity: ≤ 75%

    Stored in well-ventilated room without corrosion gas

  • Power supply

    110-240VAC, 50/60 Hz, 30 VA max

IN

© Copyright 2021 Shenzhen Zhonghe Headway Bio-Sci & Tech Co., Ltd.